Zum Hauptinhalt springen

Self-Diagnosis and Error Codes

ORCA Level Sensors include the following diagnosis features:

  • Self-Test: When triggered by the respective IO-Link System Command, the RGB LED is checked electrically.
  • Monitoring of Supply and internal Voltages and MCU Temperature
  • Overload Detection on digital and analog outputs

Detected errors are indicated via IO-Link Events and/or in the Error Code IO-Link Parameter, as well as by blinking patterns of the LED.

Error Codes

Blink CodeIO-Link Error CodeDescription
10x0001Internal error
20x0002Error with intermediate voltage
40x0008Supply voltage overrun / underrun
80x0080Parameter memory error
90x0100Parameter error
120x0800LED error
130x1000Overload on digital output
0x2000Overload on analog output
150x4000Temperature overrun

Revision History

Rev. A – 2024-04-16

  • Initial release