ISDU Indices
Access Rights: ro – Read Only, rw – Read/Write, wo – Write Only
System Command
| Name | Index | Bytes | Access | Values | Description |
|---|---|---|---|---|---|
| System Command | 2 | 1 | wo | see Events & Commands |
Identification
| Name | Index | Bytes | Access | Values | Description |
|---|---|---|---|---|---|
| Vendor Name | 16 | 23 | ro | CAPTRON Electronic GmbH | |
| Product Name | 18 | 5 | ro | CALIS | |
| Product Text | 20 | 17 | ro | order ID | |
| Product ID | 19 | 12 | ro | CAS-MQEU-M01 | |
| Serial Number | 21 | 13 | ro | ||
| Hardware Revision | 22 | 4 | ro | 0001 | |
| Firmware Revision | 23 | 4 | ro | V3.x | |
| Application-specific Tag | 24 | 32 | rw | ||
| Function Tag | 25 | 32 | rw | ||
| Location Tag | 26 | 32 | rw | ||
| Hardware Identification Key | 17342 | 9 | ro | A0001001C |
Measurement Configuration
| Name | Index | Bytes | Access | Values | Description |
|---|---|---|---|---|---|
| Overfill Warning Distance | 333 | 2 | rw | 0 ... 1200 [mm] |
Container Teach-In
High Fill Level
| Name | Index | Bytes | Access | Values | Description |
|---|---|---|---|---|---|
| Container High Fill Level | 287 | 1 | rw | 0 ... 100 [%] | Fill level in percent of High Level reference point. |
| Distance "High Level" | 289 | 2 | rw | 0 ... 1200 [mm] | Sensor value for High Level reference point. Will be set to current distance when triggering "Calibrate High Level" command. |
Low Fill Level
| Name | Index | Bytes | Access | Values | Description |
|---|---|---|---|---|---|
| Container Low Fill Level | 286 | 1 | rw | 0 ... 100 [%] | Fill level in percent of Low Level reference point. |
| Distance "Low Level" | 288 | 2 | rw | 0 ... 1200 [mm] | Sensor value for Low Level reference point. Will be set to current distance when triggering "Calibrate Low Level" command. |
Additional Reference Point 1
| Name | Index - Subindex | Bytes | Access | Values | Description |
|---|---|---|---|---|---|
| Level | 328 - 1 | 1 | rw | -1 - not set, 0 ... 100 [%] | Fill level in percent for optional additional reference point 1. |
| Distance | 328 - 2 | 4 | rw | 0 - not set, 1 ... 1200 [mm] | Distance for optional additional reference point 1. |
Additional Reference Point 2
| Name | Index - Subindex | Bytes | Access | Values | Description |
|---|---|---|---|---|---|
| Level | 329 - 1 | 1 | rw | -1 - not set, 0 ... 100 [%] | Fill level in percent for optional additional reference point 2. |
| Distance | 329 - 2 | 4 | rw | 0 - not set, 1 ... 1200 [mm] | Distance for optional additional reference point 2. |
Additional Reference Point 3
| Name | Index - Subindex | Bytes | Access | Values | Description |
|---|---|---|---|---|---|
| Level | 330 - 1 | 1 | rw | -1 - not set, 0 ... 100 [%] | Fill level in percent for optional additional reference point 3. |
| Distance | 330 - 2 | 4 | rw | 0 - not set, 1 ... 1200 [mm] | Distance for optional additional reference point 3. |
Additional Reference Point 4
| Name | Index - Subindex | Bytes | Access | Values | Description |
|---|---|---|---|---|---|
| Level | 331 - 1 | 1 | rw | -1 - not set, 0 ... 100 [%] | Fill level in percent for optional additional reference point 4. |
| Distance | 331 - 2 | 4 | rw | 0 - not set, 1 ... 1200 [mm] | Distance for optional additional reference point 4. |
Pin 4 Configuration
| Name | Index | Bytes | Access | Values | Description |
|---|---|---|---|---|---|
| Pin 4 Function | 316 | 1 | rw | 0 - NPN, 1 - PNP, 2 - PushPull | NPN: Output signal is pulled down to 0V when output is on. PNP: Output signal is pushed up to +VDC when output is on. PushPull: Output signal is pushed up to +VDC when output is on and is pulled down to 0V when it is off. |
| Output Function | 319 - 1 | 1 | rw | 0 - NO (Normally Open), 1 - NC (Normally Closed) | NO: Output will close when fill level is above set point. NC: Output will open when fill level is above set point. |
| Output Set Point | 319 - 2 | 1 | rw | 0 ... 100 [%] | Fill level above which Output will switch ON. With a value of 100%, Output will never switch on. |
| Output Hysteresis | 319 - 3 | 1 | rw | 0 ... 100 [%] | Output will switch OFF when fill level is below Set Point minus this value. |
| Output Minimum Impulse Time | 319 - 4 | 4 | rw | 10 ... 300000 [ms] | The minimal time (ms) the output signal will toggle when set or reset point is crossed. |
LED
| Name | Index | Bytes | Access | Values | Description |
|---|---|---|---|---|---|
| LED Brightness | 285 | 1 | rw | 1 ... 100 [%] | Brightness of LED in percent. |
Observation & Diagnosis
| Name | Index | Bytes | Access | Values | Description |
|---|---|---|---|---|---|
| Supply Voltage | 256 | 2 | ro | 0 ... 65535 [0.001 V] | |
| Sensor Temperature | 257 | 2 | ro | -32768 ... 32767 [0.1 °C] | |
| Device Status | 36 | 1 | ro | 0 ... 4 | Device Status according to IO-Link Specification B.2.20 |
| Detailed Device Status | 37 | 24 | ro | Device Status according to IO-Link Specification B.2.21 | |
| Error Code | 282 | 2 | ro | 0 ... 65535 | See Diagnostics |
| Charge Code | 280 | 4 | ro | 0 ... 4294967295 |