Skip to main content

IO-Link Process Data

Until valid Process Data have been received, CANEO series5x devices control their display according to the configured scene triggers.

When Process Data is marked invalid by the master, the recent valid data will be used for display control.

info

IO-Link Bit Offset counts from the last byte of the data array.

Process Data Input​

64 bit / 8 bytes

Structure​

Byte01234567
Bit Offset32241680
DatareservedZone 4 actuatedZone 3 actuatedZone 2 actuatedZone 1 actuated

Field Reference​

Bit OffsetNameDatatypeValuesInfo
0Zone 1 actuated8-bit UIntegerT0 ... 1
8Zone 2 actuated8-bit UIntegerT0 ... 1
16Zone 3 actuated8-bit UIntegerT0 ... 1
24Zone 4 actuated8-bit UIntegerT0 ... 1
32Reserved32-bit UIntegerT

Process Data Output​

128 bit / 16 bytes

Structure​

Byte0123456789101112131415
Bit Offset807264321680
DataText to displayText ColorText SelectNumber to displayActive ScenesreservedScene Selection Mode

Field Reference​

Bit OffsetNameDatatypeValuesInfo
0Scene Selection Mode8-bit UIntegerT

0 - Local Data
1 - Process Data

Local Data : Scenes are activated by the SENSORswitch according to the configured triggers.
Process Data : Scenes are active according to the bits of Active Scenes Process Data field.

8reserved
16Active Scenes (Bitmask)16-bit UIntegerT0 ... 65535

Bit 0 - Scene 1
Bit 1 - Scene 2
...

32Number to display32-bit IntegerT-9999...99999
64Text Select8-bit UIntegerT

0 - From Scene
1 - Number given
2 - Text given

From Scene : Display shows the text as configured in that active scene that has the greatest number.
Number given : Display shows the number given in these Process Data.
Text given : Display shows the text given in these Process Data.

72Text Color8-bit UIntegerT

0 - Off
1 - Red
2 - Green
3 - Blue
4 - Yellow
5 - Magenta
6 - Cyan
7 - White
8 - Orange
9 - Violet
10 - Turquoise
11 - Clean Blue
128 - Custom Color 1
129 - Custom Color 2
130 - Custom Color 3
131 - Custom Color 4

80Text to displayStringT[6]