Zum Hauptinhalt springen

CANEO series4x + Allen-Bradley — Add-On Instruction Guide

This guide walks through integrating a CANEO series4x button with an Allen-Bradley ControlLogix or CompactLogix controller in Studio 5000 Logix Designer. By the end you'll be reading the button's state from ladder logic and writing LED scenes, colors, numbers, and display text to it — all through a CAPTRON Add-On Instruction (AOI) that hides the byte-level plumbing.

Most IO-Link masters on EtherNet/IP hand the controller its process data as one flat SINT array covering every port on the block. Several CANEO series4x fields — the actuation count, the displayed number, and the active LEDs — are larger than one byte, and some masters also swap the byte order. The AOI takes care of both: you point it at the master's raw arrays and tell it where your port starts, and it gives you back two clean, named structures to read and write.

Prerequisites​

Before starting, make sure:

  • Studio 5000 Logix Designer is installed and you have a project open for your controller. This example uses a 5069-L306ER CompactLogix on firmware v38.
  • An IO-Link master is configured under I/O Configuration and its input and output data are visible as controller tags. This example uses a MURR IMPACT67 Pro E DIO8 IOL8 M12L 5P (54631).
  • The CANEO series4x is wired to an IO-Link port on the master (this example uses port 2).
  • You have downloaded CANEOseries4x_V34_AOI.zip and unzipped it to get the two AOI files (see Download at the end of this guide).
  • You have the CANEO series4x process data layout handy for the meaning of each value: series4x Process Data.

Choose the LED control mode​

The series4x only uses the output process data you send it if the button is set to accept it. This is the IO-Link parameter LED Control Mode, which you'll find in the IODD under LEDs → LED Control Mode:

LED Control ModeWhat the button showsAOI to use
Automatic Scene selectionScenes are selected by the button's own triggers. The output process data is unused.—
Scene controlled by IO-Link Process DataThe LED ring and display show one of the eight scenes configured in the IODD. You pick the scene, and optionally the number or text, from the PLC.AOI_CANEOseries4x_Scene_Control_v34
Advanced control by IO-Link Process DataThe PLC sets everything directly: which LEDs are on, their RGB color, effect, brightness, and each display digit.AOI_CANEOseries4x_Advanced_Control_V34

Scene control covers most applications. Use Advanced control when eight scenes aren't enough — for example to light individual LEDs or build a scrolling text. For details on each mode, see series4x LED (and Display) Control.

Pick one AOI per button. The two AOIs share the same input structure, but their output structures are different and match only their own LED Control Mode. Set the LED Control Mode on the button first, then use the matching AOI.


1. Import the Add-On Instructions​

In the Controller Organizer, expand Assets, then right-click Add-On Instructions and choose Import Add-On Instruction….

Right-click menu on Add-On Instructions with Import Add-On Instruction highlighted

Browse to the unzipped files and import CANEOseries4x_Scene_Control_v34_AOI.L5X, CANEOseries4x_Advanced_Control_V34_AOI.L5X, or both. Confirm the import dialog that follows.

Import Add-On Instruction dialog showing the CANEO series4x AOI files

After the import, the AOIs appear under Add-On Instructions, and their user-defined data types (UDTs) appear under Data Types → User-Defined:

  • CANEOseries4x_PDIN — the process data coming from the button. Used by both AOIs.
  • CANEOseries4x_PDOUT_Scene_Controlled — the process data going to the button in Scene control mode.
  • CANEOseries4x_PDOUT_Advanced_Control — the process data going to the button in Advanced control mode.

2. AOI parameters​

Open the AOI definition and switch to the Parameters tab to see what the instruction expects. Both AOIs have the same parameters — only the data type of IOL_PD_OUT differs.

Add-On Instruction Definition showing the AOI_CANEOseries4x_Advanced_Control_V34 parameters

ParameterData typeDescription
IOL_PD_INCANEOseries4x_PDINStructure the AOI fills with the CANEO series4x input process data. Read the button's state from here. See Reading the button.
IOL_PD_OUTCANEOseries4x_PDOUT_Scene_Controlled or CANEOseries4x_PDOUT_Advanced_ControlStructure you write to. The AOI packs it into the output process data. See Scene control and Advanced control.
IOL_PD_IN_RAWSINT[16]The raw IO-Link input process data array from the IO-Link master (as defined by the master's EDS file).
IOL_PD_OUT_RAWSINT[16]The raw IO-Link output process data array from the IO-Link master (as defined by the master's EDS file).
IOL_PD_IN_RAW_START_INDEXDINTIndex of the first input byte of the port the CANEO series4x is connected to. Consult your IO-Link master's manual for the byte layout.
IOL_PD_OUT_RAW_START_INDEXDINTIndex of the first output byte of the port the CANEO series4x is connected to. Consult your IO-Link master's manual for the byte layout.
byteswapBOOLSet to 1 if your IO-Link master swaps the byte order of the process data. Default is 0 (no swap).

Do I need byte swapping? IO-Link masters don't all format process data the same way. Some present each 16-bit word with its two bytes swapped. Masters from Turck, IFM, and Comtrol commonly do this. If display digits appear in swapped pairs, or values like the actuation count look wrong, set byteswap to 1.


3. Add the AOI to your routine​

Open your routine (here MainProgram → series4x) and add the AOI that matches your LED Control Mode to a rung — you'll find both in the Toolbox under Add-On. Every operand starts as a question mark.

AOI_CANEOseries4x_Scene_Control_v34 placed on rung 0 with all operands unassigned

Fill in the operands one by one. For the tags that don't exist yet, right-click the question mark and choose New Tag:

  1. AOI instance — create a new tag of the AOI's type (e.g. AOI_port2_MURR). Use one instance per button.
  2. IOL_PD_IN — create a new tag of type CANEOseries4x_PDIN (e.g. CD40_PDIN_port2).
  3. IOL_PD_OUT — create a new tag of the matching output type (e.g. CD40_PDOUT_port2 of type CANEOseries4x_PDOUT_Scene_Controlled).
  4. IOL_PD_IN_RAW / IOL_PD_OUT_RAW — select the IO-Link master's input and output data arrays from the Controller Tags.
  5. IOL_PD_IN_RAW_START_INDEX / IOL_PD_OUT_RAW_START_INDEX — enter the index of the first input and output byte of the port the CANEO series4x is connected to. These values are specific to your IO-Link master. If your master (or the master manufacturer's own AOI) already gives you a separate array per port, the start index is most likely 0 — see Using integer arrays.
  6. byteswap — 0 or 1, depending on your master (see above).

Example: MURR IMPACT67 (54631), port 2​

AOI configured for a MURR 54631 IO-Link master, port 2

OperandValueWhy
AOI instanceAOI_port2_MURRNamed after the port and the master it serves.
IOL_PD_INCD40_PDIN_port2Named after the part number (CD40), the type of process data, and the port.
IOL_PD_OUTCD40_PDOUT_port2Same naming scheme for the output side.
IOL_PD_IN_RAWMurr54631:I1.DataThe MURR block's complete input data array, stored under Controller Tags.
IOL_PD_OUT_RAWMurr54631:O1.DataThe MURR block's complete output data array.
IOL_PD_IN_RAW_START_INDEX90First input byte of port 2 in the MURR input array.
IOL_PD_OUT_RAW_START_INDEX66First output byte of port 2 in the MURR output array.
byteswap0The MURR block does not swap bytes.

In this example the entire MURR data array is passed in, and the start indexes tell the AOI where port 2's data begins inside it. To connect a button on another port, add a second AOI instance with its own PDIN/PDOUT tags and that port's start indexes.


4. IOL_PD_IN — reading the button​

CANEOseries4x_PDIN is the same for both AOIs. It holds the button's actuation state, its pin states, and its sensor readings.

CD40_PDIN_port2 expanded showing the process data input members

MemberData typeDescription
Surronding_BrightnessSINTAmbient brightness measured by the button's light sensor, in percent (0…100).
Actuation_StrengthSINTDamping of the sensor, in percent (0…100).
Actuation_CountINTNumber of actuations since the button was powered on. Resets on restart and after 65535.
Actuation_FlagSINTSensor actuation state: 0 = idle, 1 = actuated.
Pin_5SINTInput 2 (E2) pin state: 4 = input off, 5 = input on, 8 = pin unused.
Pin_4BOOLOUT pin state: 0 = output off, 1 = output on.
Pin_2SINTInput 1 (E1) pin state: 4 = input off, 5 = input on, 8 = pin unused.

Actuation_Count above 32767 shows as negative. The button counts up to 65535, but INT in Logix is signed. Past 32767 the tag rolls over to negative values. If you need the full range, copy it into a DINT and add 65536 when it's negative.

For the full input layout, see series4x Process Data.


5. IOL_PD_OUT — Scene control mode​

Use CANEOseries4x_PDOUT_Scene_Controlled with AOI_CANEOseries4x_Scene_Control_v34 when the LED Control Mode is Scene controlled by IO-Link Process Data.

CD40_PDOUT_port2 expanded showing the Scene control output members

MemberData typeDescription
TextSTRINGText shown on the 4-digit, 7-segment display — up to 4 characters. Shown when Display_Mode = 2.
Displayed_NumberINTNumber shown on the display, 0…9999. Shown when Display_Mode = 1.
Display_ModeSINTWhat the display shows: 0 = the text defined in the active scene (IODD), 1 = the number from Displayed_Number, 2 = the characters from Text.
LED_SceneSINTActive LED scene, 0…7. Write -1 (255) to let the button select the scene from its actuation and input pins instead.

The scenes themselves — color, effect, and display text for each of the eight — are configured in the IODD. See series4x LED Scenes.

Display fields apply to Display variants only. On a series4x without a display, Text, Displayed_Number, and Display_Mode have no effect.


6. IOL_PD_OUT — Advanced control mode​

Use CANEOseries4x_PDOUT_Advanced_Control with AOI_CANEOseries4x_Advanced_Control_V34 when the LED Control Mode is Advanced control by IO-Link Process Data.

CD40_PDOUT_port2_ADVANCED expanded showing the Advanced control output members

MemberData typeDescription
Display_BrightnessSINTBrightness of the 7-segment display in percent (0…100). Write -1 (255) for automatic brightness.
Display_Digit_4SINTCharacter for digit 4, as an ASCII code.
Display_Digit_3SINTCharacter for digit 3, as an ASCII code.
Display_Digit_2SINTCharacter for digit 2, as an ASCII code.
Display_Digit_1SINTCharacter for digit 1, as an ASCII code.
Effect_FrequencySINTFrequency of the LED effect in 1/10 Hz, 1…60 (0.1…6 Hz). 0 = default frequency.
LED_EffectSINTLED effect number. See the LED Effects reference.
LED_Color_BSINTBlue component of the LED color, 0…255.
LED_Color_GSINTGreen component of the LED color, 0…255.
LED_Color_RSINTRed component of the LED color, 0…255.
LED_BrightnessSINTBrightness of the LED ring in percent (0…100). Write -1 (255) for automatic brightness.
Active_LedsINTBitmask of the LEDs that are on. Bit 0 = LED 1 (top left), increasing clockwise. A 1 bit turns that LED on; -1 turns all 16 on.

Values above 127 are written as negatives. SINT in Logix is signed (-128…127), but most of these fields take 0…255. To send a value above 127, write it minus 256 — for example -1 for 255 (full color or automatic brightness) or -128 for 128. The same applies to Active_Leds: -1 sets all 16 bits.

The display digits take ASCII codes, not characters. Write the number of the character, not the character itself — for example 65 for A, 48 for 0, or 64 for @. The full list of characters the 7-segment display can show, and how to build custom segment patterns, is in series4x Display Content.


7. Usage example — Scene control​

The ladder logic below switches LED scenes based on the button's OUT pin and shows a number on the display.

Ladder logic switching LED scenes on Pin_4 and writing a number to the display

  • Rung 0 — calls AOI_CANEOseries4x_Scene_Control_v34. It must be scanned on every cycle, so leave it unconditional.
  • Rung 1 — while the OUT pin is off (XIO CD40_PDIN_port2.Pin_4), MOVE 1 into LED_Scene — scene 1 is active.
  • Rung 2 — while the OUT pin is on (XIC CD40_PDIN_port2.Pin_4), MOVE 2 into LED_Scene — scene 2 is active.
  • Rung 3 — sets Display_Mode to 1 (show the number) and Displayed_Number to 123.

To show text instead, set Display_Mode to 2 and write up to 4 characters to Text.


8. Usage example — Advanced control​

The ladder logic below lights the whole LED ring green, turns it red while the OUT pin is on, and writes AAAA to the display.

Ladder logic setting LED colors on Pin_4 and writing ASCII codes to the display digits

  • Rung 0 — calls AOI_CANEOseries4x_Advanced_Control_V34 with its own output tag, CD40_PDOUT_port2_ADVANCED. Leave it unconditional.
  • Rung 1 — sets Display_Brightness to 100, Active_Leds to -1 (all 16 LEDs on), and LED_Brightness to 100.
  • Rung 2 — while the OUT pin is on (XIC CD40_PDIN_port2.Pin_4), sets LED_Color_G to 0 and LED_Color_R to -1 (255) — the ring is red.
  • Rung 3 — while the OUT pin is off (XIO CD40_PDIN_port2.Pin_4), sets LED_Color_R to 0 and LED_Color_G to -1 (255) — the ring is green.
  • Rung 4 — writes 65 (the ASCII code for A) to Display_Digit_1 through Display_Digit_4, so the display shows AAAA.

To blink or animate the ring, write an effect number to LED_Effect and a speed to Effect_Frequency.


9. Using integer arrays and an IO-Link master AOI​

Some IO-Link masters, such as the IFM AL1322, import their data as an INT array instead of a SINT array, and some come with their own AOI that pulls one port's data into a separate array. The CANEO series4x AOIs expect SINT arrays, so convert with a CPS instruction on the way in and back on the way out:

  1. The master manufacturer's AOI (if any) extracts the port's data into its own array.
  2. CPS copies the input array into a SINT array for IOL_PD_IN_RAW.
  3. The CANEO series4x AOI runs, with both start indexes set to 0 because the arrays already hold only that port's data.
  4. CPS copies the SINT array from IOL_PD_OUT_RAW back into the master's output array.

Set byteswap to 1 for masters that swap bytes, such as IFM. For a full walkthrough with screenshots, see step 7 of the CANEO series5x + Allen-Bradley guide. The same steps apply to the series4x.


The AOIs were created and tested with the following IO-Link masters:

  • MURR IMPACT67 Pro E DIO8 IOL8 M12L 5P (54631)
  • IFM AL1322 (byte swap enabled — see step 9)
  • SICK SIG300

Other IO-Link masters on EtherNet/IP should work as long as you set the correct start indexes and byteswap value for that master.


Reference​


Download: Add-On Instructions​

Download the CAPTRON Add-On Instructions used in this guide. The zip contains both AOIs — CANEOseries4x_Scene_Control_v34_AOI.L5X and CANEOseries4x_Advanced_Control_V34_AOI.L5X — and each one includes its data types. Unzip it and import the .L5X file you need as described in step 1.

CANEOseries4x_V34_AOI.zip